web tension control systems
CONTROLLERS

WEB TENSION CONTROLLER
Ideal to correct variations in tension, controllers are suitable for various applications in both closed-loop and open-loop systems
The tension controller receives the data from the sensor or load cell and forwards it to the brake.
In closed loop systems, web tension controllers compare the web tension value detected from the load cells with the ‘set point’ and send the input to the brake or motor so to adjust the web tension.
In open loop systems, the web tension value can be obtained by the ultrasonic sensor, able to detect the reel diameter, or by a potentiometer connected to a dancer roller.
CONTROLLERS models

Web tension controllers
WEB TENSION CONTROLLER
DatasheetControl panel
- Complete management of PID functions
- Compensation of reels inertia in different stages
- Programmable acceleration and deceleration time instead of the set point
- Non-stop roll change management program
| TECHNICAL DATA | |
| supply | 24 Vdc (± 10%) |
| power | 8W max |
| cells analogue input | 1 max nr 2 load cells |
| analogue input | 1 dancer roller or remote setpoint or line speed |
| analogue output (2X) | 1 tension proportional or dancer roller piston control |
| Digital relay outputs | 2 for alarms |
| IP protection class | IP20 – Case / IP52 – Front Panel |
| Working temperature | 50 °C |
| Weight | 400 g |


Web tension controllers
ISOBOX
Tension control box
The Isobox is an integrated system for the automatic tension regulation of the Isomatic control panel and Ep converter transducer. Thanks to its high flexibility, it can be customized to suit diverse kind of applications and can be configured to work with load cells, dancer roller or ultrasonic sensor for the web tension control both in the closed-loop system and the open-loop system.
Isobox is easy to use and ready to mount.
| TECHNICAL DATA | |
| input supply | 220÷240 V; 50÷60 Hz; 3,2 A |
| input pressure | max 8 bar |
| input load cell signal | 2×6 pin connector EN 60529 |
| output supply | 24 V; 6,25 A |
| output pressure | 0÷6 bar |
| drives | left brake and right brake; manual and automatic mode |
| security | on/off electrical button |
| regulation | automatic regulation by panel and manometer; manual regulation by manual regulator and termometer |
| operating temperatures | 0÷50 °C |